SECURSTOR ASTRA ES 115
Reported Event
Corrective Action
Host Interface Controller
Host-interface controller
has detected bus reset
The initiator sent a reset command. If this message
appears repeatedly, contact Technical Support.
Host-interface controller
has encountered an
unrecoverable error
Restart the Astra ES.
Host-interface controller
has received an abort-
task/ abort task set/clear
task set command.
Result of user action. Normal.
Host-interface controller
has received an clear
ACA command.
Result of clearing an auto contingent alliance
condition. If this message appears repeatedly,
contact Technical Support.
Host-interface controller
has received a LUN reset
command.
Result of user action. Normal.
Host-interface controller
has received a bus reboot
The Astra ES rebooted itself. If this message
appears repeatedly, contact Technical Support.
Host-interface controller
has encountered an
unknown error
An unidentified error occurred. If this message
appears repeatedly, contact Technical Support
Host-interface controller
has encountered a
system error
An Astra ES system error occurred. If this message
appears repeatedly, contact Technical Support.
Host-interface controller
has encountered a fatal
error
Restart the Astra ES. If this message appears
repeatedly, contact Technical Support.
Host-interface controller
settings have changed
Result of user action. Normal.